Managing the stack (cli), Configuring stack member and nsf settings – Dell POWEREDGE M1000E User Manual
Page 157
Managing a Switch Stack
157
Managing the Stack (CLI)
This section provides information about the commands you use to manage
the stack and view information about the switch stack. For more information
about these commands, see the
PowerConnect M6220/M6348/M8024/M8024-k
CLI Reference Guide
at
Configuring Stack Member and NSF Settings
Beginning in Privileged EXEC mode, use the following commands to
configure stacking and NSF settings.
Command
Purpose
configure
Enter Global Configuration mode.
switch
current_ID
renumber
new_ID
Change the switch ID number. The valid range is 1-10.
NOTE:
Changing the ID number causes all switches in the
stack to be reset to perform Management unit renumbering.
The running configuration is cleared when the units reset.
stack
Enter Global Stack Configuration mode.
movemanagement
from_unit to_unit
Move the management switch functionality from one
switch to another.
standby
unit
Specify the stack member that will come up as the master
if a stack failover occurs.
set description
unit
Configure a description for the specified stack member.
member
unit SID
Add a switch to the stack and specify the model of the new
stack member.
•
unit - The switch unit ID
•
SID - The index into the database of the supported
switch types, indicating the type of the switch being
preconfigured. To view the SID associated with the
supported switch types, use the show supported
switchtype command in Privileged EXEC mode.
nsf
Enable nonstop forwarding on the stack.
exit
Exit to Global Config mode.
boot auto-copy-sw
Enable the Stack Firmware Synchronization feature.