Dell POWEREDGE M1000E User Manual
Page 161
Managing a Switch Stack
161
At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the Master unit.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW
Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- ---------
-------
--------
-------------------
--------
1
Stack Member
PCM6348
PCM6348
OK
9.19.0.2
2
Unassigned
PCM6348
Not Present 0.0.0.0
3
Mgmt Switch
PCM6348
PCM6348
OK
9.19.0.2
4
Stack Member
PCM6348
PCM6348
OK
9.19.0.2
SW
Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- ---------
-------
--------
-------------------
--------
1
Stack Member
PCM6348
PCM6348
OK
9.19.0.2
3
Mgmt Switch
PCM6348
PCM6348
OK
9.19.0.2
4
Stack Member
PCM6348
PCM6348
OK
9.19.0.2