beautypg.com

Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 99

background image

Status

The status of the array member disk drive. Valid values for status are:

good

The disk drive is working.

not_present

The disk drive cannot be detected. It has been removed or it has
failed.

too_large

The member disk drive is too large to be protected by one of the
hot spare disk drives that is in the pool.

Note: The size of the member disk drive is not the physical size

of the disk drive, but the size that the array manager
assigns to it. For example, if a RAID-10 array is created
from three 9 GB disk drives and one 18 GB disk drive, the
size that is assigned to each array member disk drive is 9
GB. The 18 GB disk drive can still be protected by a 9 GB
hot spare disk drive.

wrong_pool

This member disk drive of the array has been replaced with a hot
spare disk drive from another pool. This action has occurred
because no hot spare disk drive was available in this pool when
the array member disk drive failed. When all failed disk drives
have been replaced, this array member disk drive should be
exchanged with a disk drive that is in the same physical domain
as are the other disk drives in the pool (see Chapter 5, “Hot Spare
Management” on page 45).

Chapter 6. Using the RAID Array Configurator

79

|
|

|
|
|
|
|
|
|