12 on – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 113

background image

8. Select the adapter that contains the rejected disk drive.

The following menu is displayed:

Identify Rejected Array Disks

Type or select values in entry fields.
Press Enter AFTER making all desired changes.

[Entry Fields]

SSA RAID Manager

ssa0

* Rejected Array Disks

+

Flash Disk Identification Lights

yes

+

F1=HelpF2=Refresh

F3=Cancel

F4=List

F5=Reset

F6=Command

F7=Edit

F8=Image

F9=Shell

F10=Exit

Enter=Do

9. Select yes in the Flash Disk Identification Lights field.

10. Press the List key to list the disk drives.

11. From the displayed list, select the disk drives that you want to identify.

The Check light flashes on each disk drive that you have selected.

12. If the disk drive was rejected from the array because the disk drive itself has failed,

go to step 13 on page 94.

If the disk drive was rejected from the array because some other part has failed
(for example, a power supply unit, or an SSA cable):

a. Correct the problem, or call your service representative.

b. Add the disk drive to the array (see “Adding a Disk Drive to an SSA RAID

Array” on page 140).

c. Run system diagnostics to verify that the repair is successful.

Alternatively:

a. Change the use of the original disk drive so that it becomes a hot spare disk

drive (see “Changing or Showing the Use of an SSA Disk Drive” on page 144).

b. Install a replacement disk drive (see “Installing a Replacement Disk Drive” on

page 95).

c. Run system diagnostics to verify that the repair is successful.

Chapter 6. Using the RAID Array Configurator

93