Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual
Page 445

SRN
Problem
Possible Causes
48600
Description: All the member disk drives of an array are not on the same
SSA loop. The array is in the Exposed state, and write operations to the
array are inhibited.
Action: All the member disk drives of an array must be on the same SSA
loop. Find all the members of the array:
1. Type
smitty devices
and press Enter.
2. Select SSA RAID Arrays.
3. Select List/Identify SSA Physical Disks.
4. Select List Disks in an SSA RAID Array.
5. Select the hdisk that is in the Exposed state, and note all the pdisks.
If necessary, use the Identify function to identify the disk drive.
6. Move all the member disk drives to the same SSA loop.
SSA loop configuration
problem.
48700
Description: All the member disk drives of an array are not on the same
SSA loop. The array is in the Offline state.
Action: All the member disk drives of an array must be on the same SSA
loop. Find all the members of the array:
1. Type
smitty devices
and press Enter.
2. Select SSA RAID Arrays.
3. Select List/Identify SSA Physical Disks.
4. Select List Disks in an SSA RAID Array.
5. Select the hdisk that is in the Offline state, and note all the pdisks. If
necessary, use the Identify function to identify the disk drives.
6. Move all the member disk drives to the same SSA loop.
SSA loop configuration
problem.
Chapter 18. SSA Problem Determination Procedures
425
|
|
|
|