beautypg.com

Installing a replacement disk drive, Installing a replacement disk drive” on – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 115

background image

Installing a Replacement Disk Drive

1. Physically install the replacement disk drive (see the Operator Guide or Service

Guide for the unit).

2. If the failed disk drive has been exchanged for a hot spare disk drive, change the

use of the new disk drive to Hot Spare Disk (see “Changing or Showing the Use
of an SSA Disk Drive” on page 144).
Run system diagnostics to verify that the disk
drive is working correctly.

If no hot spare disk drive was available when the original disk drive failed, the
array is now in the Exposed state or in the Degraded state. Change the use of the
new disk drive to Array Candidate Disk (see “Changing or Showing the Use of an
SSA Disk Drive” on page 144),
and continue with this procedure to add the new
disk drive to the array.

3. For fast path, type

smitty exssaraid

and press Enter.

Otherwise:

a. Select Change Member Disks of an SSA RAID Array from the SSA RAID

Arrays menu.

b. Select Swap Members of an SSA RAID Array.

4. A list of arrays is displayed:

Change Member Disks of an SSA RAID Array

Move cursor to desired item and press Enter.

Remove a Disk from an SSA RAID Array
Add a Disk to an SSA RAID Array
SwapMembers of an SSA RAID Array

--------------------------------------------------------------------------

|

SSA RAID Array

|

|

|

| Move cursor to desired item and press Enter.

|

|

|

|

hdisk3

00703795D3F7C0G system good

9.2GB raid_1

|

|

hdisk4

00703784C540C0O system degraded

27.5GB raid_10

|

|

hdisk5

007037943540C0O system good

27.5GB raid_10

|

|

|

| F1=HelpF2=Refresh

F3=Cancel

|

| F8=Image

F10=Exit

Enter=Do

|

| /=Find

n=Find Next

|

--------------------------------------------------------------------------

Select the array into which you are installing the replacement disk drive. This array
is listed as exposed or degraded.

Chapter 6. Using the RAID Array Configurator

95