3. A list of rejected disk drives is displayed:
COMMAND STATUS
Command: OK
stdout: yes
stderr: no
Before command completion, additional instructions may appear below.
pdisk4
08005AEA030D00D member
rejected
2.3G
Physical disk
F1=HelpF2=Refresh
F3=Cancel
F6=Command
F8=Image
F9=Shell
F10=Exit
/=Find
n=Find Next
4. Check the list of rejected disk drives against other error reports to find out why the
disk drive was rejected from the array.
5. If you know the physical location of the rejected disk drive, go to step 12 on
page 93. Otherwise, go to step 6 to identify the rejected disk drive.
6. For fast path, type
smitty ifssaraid
and press Enter.
Otherwise:
a. Return to the List/Identify SSA Physical Disks menu.
b. Select Identify Rejected Array Disks.
7. The list of adapters that was displayed in step 2 on page 91 is displayed again.
92
User’s Guide and Maintenance Information