Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual
Page 359
4. Refer to Figure 53.
5. Locate the battery assembly so that the two lugs
1
are under the edges of the
small slots
2
, and the clip
3
is over the larger slot
4
.
6. Carefully press the battery assembly downward until the clip latches under the edge
of the slot.
7. Reinstall the Fast-Write Cache Option card (see “Installing the Fast-Write Cache
Option Card of an Advanced SerialRAID Adapter” on page 334).
8. Reinstall the adapter into the using system (see the Installation and Service Guide
for the using system).
Note: The battery on the Fast-Write Cache Option Card might be fully discharged.
If it is, the diagnostics fail and generate SRN 42529 (see “Service Request
Numbers (SRNs)” on page 411). While the battery is discharged, the adapter
can be used; the Fast-Write Cache feature, however, remains disabled until
the battery is charged. The battery becomes fully charged approximately one
hour after the adapter is connected to the power.
9. You must now reset the battery-age counter. To do this action, go to the command
line and type the command:
ssa_format -l SSA_Adapter -b
where
SSA_Adapter
is the name of the adapter onto which you have installed the
Fast-Write Cache Option Card; for example, ssa0.
1
1
2
2
3
4
Figure 53. Installing the Battery Assembly
Chapter 15. Removal and Replacement Procedures
339