Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual
Page 434

SRN
Problem
Possible Causes
2A004
Description: Async code 04 has been received. Probably, a software error
has occurred.
Action: Go to “Software and Microcode Errors” on page 441 before
exchanging any FRUs.
Software error.
Possible FRUs:
Device (50%) (“Exchanging
Disk Drives” on page 319).
SSA adapter card (50%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
2A005
to
2A206
Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
2FFFF
Description: An async code that is not valid has been received.
Action: Go to “Software and Microcode Errors” on page 441.
Software error.
300C0
301C0
Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
303FE
Description: A disk drive microcode error has been detected.
Action: Go to “Software and Microcode Errors” on page 441.
Software error.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
303FF
Description: An SCSI status that is not valid has been received.
Action: Go to “Software and Microcode Errors” on page 441.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
31000
Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
33PAA
Description: Excessive link reconfigurations have been detected.
Action: Go to “MAP 2323: SSA Intermittent Link Error” on page 450.
Possible FRUs:
External SSA cables
(30%).
Internal SSA connections
(30%) (enclosure service
information).
Device (30%) (“Exchanging
Disk Drives” on page 319).
SSA adapter card (10%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
414