3. The following information is displayed:

SwapMembers of an SSA RAID Array

Type or select values in entry fields.
Press Enter AFTER making all desired changes.

[Entry Fields]

SSA RAID Manager

ssa0

SSA RAID Array

hdisk3

Connection Address / Array Name

09523173A02137K

* Disk To Remove

+

* Disk To Add

+

F1=HelpF2=Refresh

F3=Cancel

F4=List

F5=Reset

F6=Command

F7=Edit

F8=Image

F9=Shell

F10=Exit

Enter=Do

Select Disk to Remove, and press the List key.

4. From the displayed list, select the disk drive that you want to remove, and press

Enter.

Note: If the disk drive that you are replacing has been removed, or the array has

rejected it, it is listed as BlankReservedZ.

5. Select Disk to Add, and press the List key.

6. From the displayed list, select the name of the disk drive that you want to add, and

press Enter.

7. Press Enter to perform the swap operation.

Chapter 6. Using the RAID Array Configurator