Page 475

background image

3. (from step 2)

Do you have any other SRN?

NO

Go to step 22 on page 467.

YES

a. Solve the problems that caused the SRN.

b. Return to step 1 on page 454.

4. (from step 2)

Find your SRN in the following table, then do the appropriate actions.

Note: If you still do not have any of these SRNs, you are in the wrong MAP.

SRN

Cause

Action

46000

An array is in the Offline state.

Go to step 5.

47000

You have more than the maximum
number of arrays allowed.

Go to step 8 on page 457.

47500

A partial loss of data has occurred.

Go to step 9 on page 458.

49000

An array is in the Degraded state.

Go to step 13 on page 460.

49100

An array is in the Exposed state.

Go to step17 on page 463.

49950

An array-copy disk drive is missing.

Go to step 23 on page 467.

5. (from step 4)

An array is in the Offline state if it contains at least one member disk drive, but does
not contain enough member disk drives to maintain data availability.

Are any disk drives missing or without power, or have any disk drives been
recabled (not necessarily by you)?

NO

Go to step 6 on page 456.

YES

Restore the original configuration:

a. Type

smitty ssaraid

and press Enter.

b. Select List All SSA RAID Arrays Connected to a RAID Manager.

The status of the array changes to Good when the adapter can find all
the member disk drives of the array.

c. Go to “MAP 2410: SSA Repair Verification” on page 475 to verify the

repair.

Chapter 18. SSA Problem Determination Procedures

455

|||