Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual
Page 412

2. Select the pdisk that you want to certify. The following instructions are displayed:
CERTIFY DISK
802405
systemname:pdisk0
AC706E9A 4GB SSA C Physical Disk Drive
Move cursor onto selection, then press
+ Set or Reset Identify.
Select this option to set or reset the Identify indicator
on the disk drive.
Certify.
Select this option to start the Certify operation.
F3=Cancel
F10=Exit
3. If you are not sure of the identification (pdisk number) of the disk drive that you
want to certify, use the Identify function to get a positive physical identification of the
disk drive (see “The Identify Function” on page 375). You can further ensure that
you have selected the correct disk drive by verifying that the serial number on the
front of the disk drive is the same as the serial number that is displayed on the
screen.
4. When you are sure that you have selected the correct disk drive, select Certify.