Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual
Page 85

5–7
Programming
This group of parameters consists of commonly viewed drive operating conditions such as
motor speed, drive output voltage, current and command frequency. All parameters in this
group are Read Only and can only be viewed.
Metering
[Output Current]
This parameter displays the output current present
at TB1, terminals T1, T2 & T3 (U, V & W).
Parameter Number
54
Parameter Type
Read Only
Display Units / Drive Units
0.1 Amp / 4096 = Rated Amps
Factory Default
None
Minimum Value
0.0
Maximum Value
200% Rated Drive Output Current
[Output Voltage]
This parameter displays the output voltage present
at TB1, terminals T1, T2 & T3 (U, V & W).
Parameter Number
1
Parameter Type
Read Only
Display Units / Drive Units
1 Volt / 4096 = Drive Rtd Volts
Factory Default
None
Minimum Value
0
Maximum Value
200% Rated Drive Output Voltage
[Output Power]
This parameter displays the output power present at
TB1, terminals T1, T2 & T3 (U, V & W).
Parameter Number
23
Parameter Type
Read Only
Display Units / Drive Units
1 kilowatt / 4096 = Drive Rated kW
Factory Default
None
Minimum Value
–200% Rated Drive Output Power
Maximum Value
+200% Rated Drive Output Power
[DC Bus Voltage]
This parameter displays the DC bus voltage level.
Parameter Number
53
Parameter Type
Read Only
Display Units / Drive Units
1 Volt / 4096 = Drive Rtd Volts
Factory Default
None
Minimum Value
0
Maximum Value
200% DC Bus Voltage Max
[Output Freq]
This parameter displays the output frequency
present at TB1, terminals T1, T2 & T3 (U, V & W).
Parameter Number
66
Parameter Type
Read Only
Display Units / Drive Units
0.01 Hertz / 32767 = Maximum Freq Forward
Factory Default
None
Minimum Value
–400.00 Hz
Maximum Value
+ 400.00 Hz
[Freq Command]
This parameter displays the frequency that the drive
is commanded to output. This command may come
from any one of the frequency sources selected by
[Freq Select 1] or [Freq Select 2].
Parameter Number
65
Parameter Type
Read Only
Display Units / Drive Units
0.01 Hertz / 32767 = Maximum Freq Forward
Factory Default
None
Minimum Value
–400.00 Hz
Maximum Value
+ 400.00 Hz