Analog out sel, Anlg out offset, Set anlg out lo] –firmware 4.01 & later – Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual
Page 106: Set anlg out hi] –firmware 4.01 & later
5–28
Programming
[Analog Out Sel]
This parameter selects the source that will drive the
analog output. This output is intended for metering
only and should not be used as process control
feedback.
Important: Firmware versions below 4.01 will have
fewer selections available.
Parameter Number
25
Parameter Type
Read and Write
Factory Default
“Frequency”
Units
Display Drive
“Frequency” 0
Zero to programmed [Maximum Freq]
“Current” 1
Zero to 200%
“Torque” 2
Zero to 200%
“Power” 3
Zero to 200%
“Voltage” 4
Zero to 200%
“% Motor OL” 5
Zero to 200%
“% Drive OL” 6
Zero to 200%
“Encoder” 7
See [Pulse/Enc Hertz]
“Speed Error” 8
See [Speed Error]
“PI Reference” 9
See [PI Reference]
“PI Feedback” 10
See [PI Feedback]
“PI Error” 11
See [PI Error]
“PI Output” 12
See [PI Output]
[Anlg Out Offset]
This parameter enables the voltage or current offset
for the analog output TB2 terminals 4 & 9. This
internal value offsets 0-20mA to 4-20mA and
0-10V to 2-10V.
Parameter Number
154
Parameter Type
Read and Write
Factory Default
“Disabled”
Units
Display Drive
“Disabled” 0
“Enabled” 1
Drive Output
Frequency
Maximum
Speed
Minimum
Frequency
0
V
0
mA
Offset
10
V
20
mA
Analog Output Signal
2
V
4
mA
Analog Out Offset
[Abs Analog Out] –Firmware 4.01 & later
This parameter selects whether a signed value or
absolute value is used for analog out.
Parameter Number
233
Parameter Type
Read and Write
Factory Default
“Enabled”
Units
Display Drive
“Disabled” 0
“Enabled” 1
[Set Anlg Out Lo] –Firmware 4.01 & later
Sets the percentage of the [Analog Out Sel] value
that equals 0V/0 mA output.
Parameter Number
234
Parameter Type
Read and Write
Display Units / Drive Units
0.1 % / 4096 = 100%
Factory Default
0.0 %
Minimum Value
–300.0 %
Maximum Value
+300.0 %
[Set Anlg Out Hi] –Firmware 4.01 & later
Sets the percentage of the [Analog Out Sel] value
that equals 10V/20 mA output.
Parameter Number
235
Parameter Type
Read and Write
Display Units / Drive Units
0.1 % / 4096 = 100%
Factory Default
100.0 %
Minimum Value
–300.0 %
Maximum Value
+300.0 %
I/O Config