beautypg.com

Parameter cross reference – by number, A–10 specifications and supplemental information – Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual

Page 150

background image

A–10

Specifications and Supplemental Information

No.

Name

Group

No.

Name

Group

No.

Name

Group

1

Output Voltage

Metering

2

% Output Curr

Metering

3

% Output Power

Metering

4

Last Fault

Metering

5

Freq Select 1

Setup + Frequency Set

6

Freq Select 2

Frequency Set

7

Accel Time 1

Setup

8

Decel Time 1

Setup

9

DC Boost Select

Advanced Setup

Control Select

4.01

Motor Control

10

Stop Select 1

Setup + Adv. Setup

11

Bus Limit En

Advanced Setup

12

DC Hold Time

Advanced Setup

13

DC Hold Level

Advanced Setup

14

Run On Power Up

Feature Select

15

Reset/Run Time

Feature Select

16

Minimum Freq

Setup + Adv. Setup

17

Base Frequency

Setup + Adv. Setup

18

Base Voltage

Setup + Adv. Setup

19

Maximum Freq

Setup + Adv. Setup

20

Maximum Voltage

Setup + Adv. Setup

21

Input Mode

Setup + I/O Config

4.01

22

MOP Increment

Frequency Set

23

Output Power

Metering

24

Jog Frequency

Frequency Set

25

Analog Out Sel

I/O Config

26

Stop Mode Used

Diagnostics

27

Preset Freq 1

Frequency Set

28

Preset Freq 2

Frequency Set

29

Preset Freq 3

Frequency Set

30

Accel Time 2

Advanced Setup

31

Decel Time 2

Advanced Setup

32

Skip Freq 1

Frequency Set

33

Skip Freq 2

Frequency Set

34

Skip Freq 3

Frequency Set

35

Skip Freq Band

Frequency Set

36

Current Limit

Setup

37

Overload Mode

Setup

38

Overload Amps

Setup

39

Flt Clear Mode

Faults

40

Line Loss Fault

Faults

41

Motor Type

Advanced Setup

42

Slip @ F.L.A.

Feature Select

43

Dwell Frequency

Feature Select

44

Dwell Time

Feature Select

45

PWM Frequency

Advanced Setup

46

Pulse/Enc Scale

Freq. Set + Enc. Fdbk.

47

Language

Feature Select

48

Start Boost

Advanced Setup

49

Break Frequency

Advanced Setup

50

Break Voltage

Advanced Setup

51

Clear Fault

Faults

52

Stop Select 2

Advanced Setup

53

DC Bus Voltage

Metering

54

Output Current

Metering

55

Input Status

Diagnostics

56

S Curve Time

Feature Select

57

S Curve Enable

Feature Select

59

Drive Status

Diagnostics

60

Drive Alarm

Diagnostics

61

Drive Type

Ratings

62

Freq Source

Diagnostics

63

Pulse/Enc Hertz

Meter. + Enc. Fdbk.

2.01

64

Set Defaults

Diagnostics

65

Freq Command

Metering + Diagnostics

66

Output Freq

Metering

67

Output Pulses

Diagnostics

69

Drive Direction

Diagnostics

70

Heatsink Temp

Metering + Diagnostics

71

Firmware Ver.

Ratings

72

Current Angle

Diagnostics

73

Preset Freq 4

Frequency Set

74

Preset Freq 5

Frequency Set

75

Preset Freq 6

Frequency Set

76

Preset Freq 7

Frequency Set

77

Speed Control

Enc. Fdbk. + Process PI

78

Traverse Period

Feature Select

79

Max Traverse

Feature Select

80

P Jump

Feature Select

81

Blwn Fuse Flt

Faults

82

Cur Lim Trip En

Faults

83

Run Boost

Advanced Setup

84

Analog Invert

Advanced Setup

Power OL Count

4.01

Metering

85

Reset/Run Tries

Feature Select

86

Fault Buffer 0

Faults

87

Fault Buffer 1

Faults

88

Fault Buffer 2

Faults

89

Fault Buffer 3

Faults

90

Analog Trim En

Advanced Setup

91

Low Bus Fault

Faults

92

Logic Mask

Masks

93

Local Mask

Masks

94

Direction Mask

Masks

95

Start Mask

Masks

96

Jog Mask

Masks

97

Reference Mask

Masks

98

Accel Mask

Masks

99

Decel Mask

Masks

100

Fault Mask

Masks

101

MOP Mask

Masks

102

Stop Owner

Owners

103

Direction Owner

Owners

104

Start Owner

Owners

105

Jog Owner

Owners

106

Reference Owner

Owners

107

Accel Owner

Owners

108

Decel Owner

Owners

109

Fault Owner

Owners

110

MOP Owner

Owners

111

Data In A1

Adapter I/O

112

Data In A2

Adapter I/O

113

Data In B1

Adapter I/O

114

Data In B2

Adapter I/O

115

Data In C1

Adapter I/O

116

Data In C2

Adapter I/O

117

Data In D1

Adapter I/O

118

Data In D2

Adapter I/O

119

Data Out A1

Adapter I/O

120

Data Out A2

Adapter I/O

121

Data Out B1

Adapter I/O

122

Data Out B2

Adapter I/O

123

Data Out C1

Adapter I/O

124

Data Out C2

Adapter I/O

125

Data Out D1

Adapter I/O

126

Data Out D2

Adapter I/O

127

Process 1 Par

Process Display

128

Process 1 Scale

Process Display

129-136 Process 1 Txt 1-8

Process Display

137

MOP Hertz

Metering

138

Pot Hertz

Metering

139

0-10 Volt Hertz

Metering

140

4-20 mA Hertz

Metering

141

Motor Mode

Diagnostics

142

Power Mode

Diagnostics

143

Flt Motor Mode

Faults

144

Flt Power Mode

Faults

145

Fault Frequency

Faults

146

Flt Driv Status

Faults

147

Drive Rtd Volts

Ratings

148

Rated CT Amps

Ratings

149

Rated CT kW

Ratings

150

4-20 mA Loss Sel

Advanced Setup

151

Maximum Speed

Encoder Feedback

152

Encoder Type

Encoder Feedback

153

Motor Poles

Encoder Feedback

154

Anlg Out Offset

I/O Config

155

Flying Start En

Feature Select

156

FStart Forward

Feature Select

157

FStart Reverse

Feature Select

158

Digital Out Sel

I/O Config

158

CR1 Out Select

4.01

I/O Config

159

Dig Out Freq

I/O Config

160

Dig Out Current

I/O Config

161

Dig Out Torque

I/O Config

162

Torque Current

Metering

163

Flux Current

Metering

165

Speed KI

Encoder Feedback

166

Speed Error

Encoder Feedback

167

Speed Integral

Encoder Feedback

168

Speed Adder

Encoder Feedback

169

Run/Accel Boost

2.01

Advanced Setup

Boost Slope

4.01

Motor Control

170

Rated Amps

Ratings

171

Rated kW

Ratings

172 EEPROM

Cksum

4.01

Diagnostics

173

Fault Alarms

Faults

174-176 CR2-4 Out Select

4.01

I/O Config

177

Motor NP RPM

Setup + Enc. Fdbk.

178

Motor NP Hertz

Setup + Enc. Fdbk.

179

Local Owner

Owners

180

Process 2 Par

Process Display

181

Process 2 Scale

Process Display

182-189 Process 2 Txt 1-8

Process Display

190

Motor NP Volts

4.01

Setup

191

Motor NP Amps

4.01

Setup

192

KI Amps

2.03

Advanced Setup

Flux Amps Ref

4.01

Motor Control

193

KP Amps

2.03

Advanced Setup

194

KI Volts

Linear List

IR Drop Volts

4.01

Motor Control

195

Slip Comp Gain

4.01

Feature Select

196

KP Volts

Linear List

198

Rated VT Amps

Ratings

199

Rated VT kW

Ratings

200

Flux Up Time

4.01

Motor Control

201

Motor OL Fault

4.01

Faults

202

Motor OL Count

4.01

Metering

203

VT Scaling

Setup

204

Ground Warning

2.01

Faults

205

Latched Alarms

2.01

Diagnostics

206

Alarm Mask

2.01

Masks

207

Fault Data

4.01

Faults

208

Time Data 1

Linear List

209

Time Data 3

Linear List

210

Time Data 5

Linear List

211

Time Data 7

Linear List

212

DC Bus Memory

Diagnostics

2.03

213

PI Config

3.01

Process PI

214

PI Status

3.01

Process PI

215

PI Ref Select

3.01

Process PI

216

PI Fdbk Select

3.01

Process PI

217

PI Reference

3.01

Process PI

218

PI Feedback

3.01

Process PI

219

PI Error

3.01

Process PI

220

PI Output

3.01

Process PI

221

KI Process

3.01

Process PI

222

KP Process

3.01

Process PI

223

PI Neg Limit

3.01

Process PI

224

PI Pos Limit

3.01

Process PI

225

PI Preload

4.01

Process PI

226

Shear Pin Fault

4.01

Faults

227

Adaptive I Lim

4.01

Setup

228

LLoss FStart

4.01

Feature Select

229

Freq Ref SqRoot

4.01

Frequency Set

230

Save MOP Ref

4.01

Frequency Set

231

Hold Level Sel

4.01

Advanced Setup

232

Current Lmt Sel

4.01

Setup

233

Abs Analog Out

4.01

I/O Config

234

Set Anlg Out Lo

4.01

I/O Config

235

Set Anlg Out Hi

4.01

I/O Config

236

2nd Drive Sts

4.01

Diagnostics

237

Set 0-10 Vlt Lo

4.01

Frequency Set

238

Set 0-10 Vlt Hi

4.01

Frequency Set

239

Set 4-20 mA Lo

4.01

Frequency Set

240

Set 4-20 mA Hi

4.01

Frequency Set

X.xx

Firmware version X.xx or later.

Located in the “Diagnostics” group for firmware versions before 2.01.

“Motor Control” group for firmware versions 4.01 & later.

Parameter Cross
Reference – By Number