5–25

Programming

[Traverse Period]

This value sets the time to complete one cycle of
speed modulation.

Parameter Number

78

Parameter Type

Read and Write

Display Units / Drive Units

0.01 Second / Seconds x 100

Factory Default

0.00 Sec

Minimum Value

0.00 Sec

Maximum Value

30.00 Sec

[Max Traverse]

This value sets the peak amplitude of speed
modulation.

Parameter Number

79

Parameter Type

Read and Write

Display Units / Drive Units

0.01 Hertz / 32767 = [Maximum Freq]

Factory Default

0.00 Hz

Minimum Value

0.00 Hz

Maximum Value

50% of [Maximum Freq]

Seconds

Hertz

Maximum Traverse (–)

Traverse

P-Jump

P-Jump (+)

P-Jump (–)

Output

Reference

Traverse Period

–20

0

10

20

30

40

50

60

20

40

Maximum Traverse (+)

Traverse Function

[P Jump]

This value sets the slip or inertia compensation
amplitude of speed modulation.

Parameter Number

80

Parameter Type

Read and Write

Display Units / Drive Units

0.01 Hertz / 32767 = [Maximum Freq]

Factory Default

0.00 Hz

Minimum Value

0.00 Hz

Maximum Value

25% of [Maximum Freq]

Feature Select