Flt power mode, Fault frequency, Flt driv status – Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual
Page 110: Faults

5–32
Programming
[Flt Power Mode]
This parameter displays the power mode active at
the time of the last fault. These values can be
helpful in troubleshooting for a condition causing a
fault.
Parameter Number
144
Parameter Type
Read Only
Factory Default
None
Units
Display Drive
“1” 1
Power up sequence in progress
“2” 2
Precharge in progress
“3” 3
Bus voltage being stored in memory
“4” 4
Ready for run cmnd. after power up
“5” 5
Power stage diagnostics running
“6” 6
Line loss detection occurred
“7” 7
Ready for run command after stop
“8” 8
Drive running
“9” 9
Motor flux decay delay
“10” 10
DC braking in progress
“11” 11
Drive fault occurred
“12” 12
Flying start search enabled
“13” 13
Deceleration in progress
“14” 14
SCR wake mode
“15” 15
SCR check mode
“16” 16
SCR wait mode
[Fault Frequency]
This parameter stores and displays the last
[Output Freq] prior to a fault.
Parameter Number
145
Parameter Type
Read Only
Display Units / Drive Units
0.01 Hertz / 32767 = Maximum Freq.
Factory Default
None
Minimum Value
0.00 Hz
Maximum Value
400.00 Hz
[Flt Driv Status]
This parameter stores and displays
the last [Drive Status] prior to a
fault.
Bits 0-7 are displayed on lower half
of line 2 on HIM display, while, bits
8-15 are displayed on the upper half
of line 2.
With drive software versions above
2.00 and a Series A (version 3.0) or
Series B HIM, a Status description
(bit ENUM) is displayed on line 1.
Parameter Number
146
Parameter Type
Read Only
Enabled
Running
Command Direction
Actual Direction
Accelerating
Decelerating
Faulted
At Speed
Bit 15
Bit 13 Bit 12 Bit 11 Bit 10 Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Alarm
0 = Reverse
1 = Forward
0 = Reverse
1 = Forward
Reference
ID
Local
Adapter ID
Reference
15 14 13 12
Freq Select 1
0
0
0
0
Preset Freq 1
0
0
0
1
Preset Freq 2
0
0
1
0
Preset Freq 3
0
0
1
1
Preset Freq 4
0
1
0
0
Preset Freq 5
0
1
0
1
Preset Freq 6
0
1
1
0
Preset Freq 7
0
1
1
1
Freq Select 2
1
0
0
0
Adapter 1
1
0
0
1
Adapter 2
1
0
1
0
Adapter 3
1
0
1
1
Adapter 4
1
1
0
0
Adapter 5
1
1
0
1
Adapter 6
1
1
1
0
Jog Frequency 1
1
1
1
Local
11 10 9
TB3
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1
4
1
0
0
5
1
0
1
6
1
1
0
Unused
1
1
1
Bit 14
Faults