Drive plc, Appendix – Lenze Global Drive PLC Developer Studio User Manual
Page 98

8.6
Code table
Drive PLC
Appendix
8−18
L
DrivePLC DE 6.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C0155 Status word 2
0
Extended status word, read only
0
Fail
1
Not assigned
2
Not assigned
3
Not assigned
4
Not assigned
5
PLC stopped
6
TRIP / QSP
7
Not assigned
8
Not assigned
9
Not assigned
10
Not assigned
11
Not assigned
12
Not assigned
13
Not assigned
14
Not assigned
15
Not assigned
C0161 Act trip
g
Current TRIP
·
See C0168/1
·
"0" is displayed for FAIL−QSP, warning and message.
C0167 Reset failmem
0
History buffer reset
0
No function
1
Delete all entries in history buffer
C0168 Fail number
g
History buffer: Error messages
·
List with error messages in order of occurrence.
All error messages
1
Current error message
2
Last error message
3
Last but one error message
4
Last but two error message
5
Last but three error message
6
Last but four error message
7
Last but five error message
8
Last but six error message
C0169 Failtime
g
History buffer: Power−up time
·
List with the power−up times until an error message
occurs in C0168/x.
·
Refers to the elapsed time meter (C0179)
0
{1 s}
65535
1
Current error message
2
Last error message
3
Last but one error message
4
Last but two error message
5
Last but three error message
6
Last but four error message
7
Last but five error message
8
Last but six error message