beautypg.com

Analog3_io (node number 13), Inputs_analog3 (analog input), Drive plc – Lenze Global Drive PLC Developer Studio User Manual

Page 37: 8 analog3_io (node number 13), System blocks, 1 inputs_analog3 (analog input)

background image

Drive PLC

System blocks

2.8

ANALOG3_IO (node number 13)

2−23

L

DrivePLC DE 6.0

2.8

ANALOG3_IO (node number 13)

2.8.1

Inputs_ANALOG3 (analog input)

This SB forms the interface for analog signals via terminal AI3, A

^.

AI3

A

AIN3_nIn_a

Inputs_ANALOG3

C0400/3

Fig. 2−13

Inputs_ANALOG3

System variables

Variable

Data type

Signal type

Address

Display

code

Display

format

Notes

AIN3_nIn_a

Integer

analog

%IW13.0

C0400/3

dec [%]

Analog input 3

Terminal assignment

Terminal

Use

Data

AI3

Analog input 3

Level:
Resolution:
Internal resistance:
Normalisation:

−10 V ... +10 V
10 bits + sign
100 k

W

±10 V º ±16384 º ±100 %

A

^

Internal ground, GND