Page 39: 2 outputs_digital (digital outputs)

background image

Drive PLC

System blocks

2.9

DIGITAL_IO (node number 1)

2−25

L

DrivePLC DE 6.0

2.9.2

Outputs_DIGITAL (digital outputs)

This SB conditions digital signals and outputs them at terminals O1 ... O4.

O1

O2

DIGOUT_bOut1_b

Outputs_DIGITAL

O3

O4

DIGOUT_bOut2_b

DIGOUT_bOut3_b

DIGOUT_bOut4_b

C0444

Fig. 2−15

Outputs_DIGITAL

System variables

Variable

Data type

Signal type

Address

Display

code

Display

format

Notes

DIGOUT_bOut1_b

Bool

binary

%QX1.0.0

C0444 − Bit1

bin

Digital outputs O1 ... O4

DIGOUT_bOut2_b

%QX1.0.1

C0444 − Bit2

DIGOUT_bOut3_b

%QX1.0.2

C0444 − Bit3

DIGOUT_bOut4_b

%QX1.0.3

C0444 − Bit4

Electrical data of the output terminals

Terminal

Use

Data

O1

freely assignable

LOW level:
HIGH level:
Output current:

0 ... +4 V
+13 ... +30 V
max. 1 A per output

O2
O3
O4

Tip!

If the user program has not been started, all outputs are defined as "LOW" after switch−on.

More detailed information about Drive PLC terminal strips/control connections can be found in the
corresponding Mounting Instructions!