C-com connection – Seiwa SW701i SW701e User Manual
Page 109
![background image](/manuals/467964/109/background.png)
111
User Manual
Autopilot Connection on Port 1
External NMEA Connection on Port 1
C-COM Connection
To connect the modem C-COM to the chart plotter with quick disconnect bracket
follow the procedure:
1. Cut the C-COM cable about 5 cm from the "T" connector:
C-COM cable cutting procedure
2. Connect the wires to the quick disconnect bracket cable as follows:
QUICK DISCONNECT BRACKET CABLE
DESCRIPTION
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
POWER SUPPLY GND
POWER SUPPLY+
C-COM
SIGNAL RETURN
C-COM
POWER GND
POWER +10-35Vdc
INPUT1+
SIGNAL RETURN-
OUTPUT1+
FUNCTION
C-COM GSM Plus CABLE
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
GND
POWER SUPPLY+
C-COM TX+
C-COM TX-
C-COM RX+
FUNCTION
C-COM Connection on Port 1
This manual is related to the following products: