AUTOPILOT DEVICE

NMEA0183/180/180CDX/INPUT+
SIGNAL RETURN

FUNCTION

QUICK DISCONNECT BRACKET CABLE

DESCRIPTION

WIRE COLOR

BLACK

RED

WHITE

GREEN

YELLOW

BROWN

GRAY

ORANGE

PINK

BLUE

POWER SUPPLY GND
POWER SUPPLY+
NMEA0183/C-COM
SIGNAL RETURN
NMEA0183/180/180CDX/C-COM
NMEA0183/C-COM
NMEA0183/180/180CDX/C-COM
NMEA0183/C-COM
NMEA0183/180/180CDX/C-COM
SIGNAL RETURN

POWER GND
POWER +10-35Vdc
INPUT1+
SIGNAL RETURN-
OUTPUT1+
INPUT2+
OUTPUT2+
INPUT3+
OUTPUT3+
SIGNAL RETURN-

FUNCTION

Autopilot Connection on Port 2

External NMEA Connection on Port 1

C-COM Connection

To connect the modem C-COM to the chart plotter with quick disconnect bracket

follow the procedure:

1. Cut the C-COM cable about 5 cm from the "T" connector:

C-COM cable cutting procedure

2. Connect the wires to the quick disconnect bracket cable as follows:

QUICK DISCONNECT BRACKET CABLE

DESCRIPTION

WIRE COLOR

BLACK

RED

WHITE

GREEN

YELLOW

POWER SUPPLY GND
POWER SUPPLY+
C-COM
SIGNAL RETURN
C-COM

POWER GND
POWER +10-35Vdc
INPUT1+
SIGNAL RETURN-
OUTPUT1+

FUNCTION

C-COM GSM Plus CABLE

WIRE COLOR

BLACK

RED

WHITE

GREEN

YELLOW

GND
POWER SUPPLY+
C-COM TX+
C-COM TX-
C-COM RX+

FUNCTION

C-COM Connection on Port 1