Festo Кабели и принадлежности User Manual
Page 99
A. Technical appendix
A−11
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Write field bus inputs of the SPC200 (I10.8 ... I13.15)
Command Message, WRC = 7
d
/ 8
d
Byte
Function
Contents for I10...11
Contents for I12...13
Byte 0
Control byte
LOAD = 1 (see section 5.2.3)
Byte 1
Subindex
Not relevant
Byte 2
Command Message type
7
d
8
d
Byte 3
Response Message type
0 (no update permitted)
Byte 4
Cmd. Data 1
ć (control byte)
I12.0 ... I12.7
Byte 5
Cmd. Data 2
I10.8 ... I10.15
I12.8 ... I12.15
Byte 6
Cmd. Data 3
I11.0 ... I11.7
I13.0 ... I13.7
Byte 7
Cmd. Data 4
I11.8 ... I11.15
I13.8 ... I13.15
Response Message
Byte
Function
Contents
Byte 0
Status byte
LOAD COMPLETED = 1 (see section 5.2.3)
Byte 1
*)
Byte 2
Fault code
See fault treatment in section 6.5
Byte 3
RMT
Copy from byte 2 of the Command Message
Byte 4
Resp. Data 1
*)
or extended fault code (see section 6.5)
Byte 5
Resp. Data 2
*)
Byte 6
Resp. Data 3
*)
Byte 7
Resp. Data 4
*)
*)
Not relevant