beautypg.com

Festo Кабели и принадлежности User Manual

Page 46

background image

4. Commissioning

4−8

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Example of function test in Record Select mode

In Record Select mode the window Control signals" enables
you to select an NC record number directly. This NC record
number corresponds to the actual NC record number in the
NC program.

Note that when a program is loaded with WinPISA the proĆ
grammed record numbers are stored beginning with N000
and with step size 1.

Example

Start NC record from line N007 of program A (ĩ = 1−signal)

2

3

1

1

Start NC record with CLK_A−signal

2

Current NC record number (here 7)

3

Entry field for NC record number
(conclude entry with ENTER)

Fig. 4/2:

Selecting an NC record (example)