Festo Кабели и принадлежности User Manual
Page 96
![background image](/manuals/464392/96/background.png)
A. Technical appendix
A−8
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Write digital nominal value M10 (only with Start/Stop)
Command Message, WRC = 3
d
/ 4
d
Byte
Function
Contents for signed 32 bit Contents for float 32 bit
Byte 0
Control byte
LOAD = 1 (see section 5.2.3)
Byte 1
Subindex
Not relevant
Byte 2
Command Message type
X=3
d
, Y=35
d
, Z=67
d
, U=99
d
X=4
d
, Y=36
d
, Z=68
d
, U=100
d
Byte 3
Response Message type
0 (no update permitted)
Byte 4
Cmd. Data 1
Position value
9999990
9999990 Ģm
Position value
9999 990
9999 990 mm
Byte 5
Cmd. Data 2
−9999990 .. +9999990 Ģm
−9999.990 ... +9999.990 mm
When written the values are
d d
fi
f
Byte 6
Cmd. Data 3
rounded to two figures after
the decimal point.
Byte 7
Cmd. Data 4
the decimal point.
Response Message
Byte
Function
Contents
Byte 0
Status byte
LOAD COMPLETED = 1 (see section 5.2.3)
Byte 1
*)
Byte 2
Fault code
See fault treatment in section 6.5
Byte 3
RMT
Copy from byte 2 of the Command Message
Byte 4
Resp. Data 1
*)
or extended fault code (see section 6.5)
Byte 5
Resp. Data 2
*)
Byte 6
Resp. Data 3
*)
Byte 7
Resp. Data 4
*)
*)
Not relevant