Festo Кабели и принадлежности User Manual
Page 102
A. Technical appendix
A−14
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Read digital nominal value M10
Command Message, WRC = 18
d
/ 19
d
Byte
Function
Contents for signed 32 bit
Contents for float 32 bit
Byte 0
Control byte
LOAD = 1 (see section 5.2.3)
Byte 1
Subindex
Not relevant
Byte 2
Command Message
type
X=18
d
, Y=50
d,
Z=82
d
, U=114
d
X=19
d
, Y=51
d
, Z=83
d
, U=115
d
Byte 3
Response Message
type
0 (no update permitted)
Byte 4
Cmd. Data 1
Not relevant
Byte 5
Cmd. Data 2
Byte 6
Cmd. Data 3
Byte 7
Cmd. Data 4
Response Message
Byte
Function
Contents for signed 32 bit
Contents for float 32 bit
Byte 0
Status byte
LOAD COMPLETED = 1 (see section 5.2.3)
Byte 1
*)
Byte 2
Fault code
See fault treatment in section 6.5
Byte 3
RMT
Copy from byte 2 of the Command Message
Byte 4
Resp. Data 1
Position value
9999990
9999990 Ģm
**)
Position value
9999 990
9999 990 mm
**)
Byte 5
Resp. Data 2
−9999990 ... +9999990 Ģm
**)
−9999.990 ... +9999.990 mm
**)
Byte 6
Resp. Data 3
Byte 7
Resp. Data 4
*)
Not relevant
**)
In the event of a fault: extended fault code (see section 6.5)