Festo Кабели и принадлежности User Manual
Page 109
A. Technical appendix
A−21
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Read fault message
Command Message, WRC = 25
d
Byte
Function
Contents
Byte 0
Control byte
LOAD = 1 (see section 5.2.3)
Byte 1
Subindex
1:
Current fault message
2...16: Diagnostic memory
Byte 2
Command Message type
CMT = 25
d
Byte 3
Response Message type
0 (no update permitted)
Byte 4...8
Cmd. Data
Not relevant
Response Message
Byte
Function
Contents
Byte 0
Status byte
LOAD COMPLETED = 1 (see section 5.2.3)
Byte 1
*)
Byte 2
Fault code
See fault treatment in section 6.5
Byte 3
RMT
Copy from byte 2 of the Command Message
Byte 4
Resp. Data 1
**)
Diagnostic word 1 (LB)
**)
Byte 5
Resp. Data 2
Diagnostic word 1 (HB)
Byte 6
Resp. Data 3
Diagnostic word 2 (LB)
Byte 7
Resp. Data 4
Diagnostic word 2 (HB)
*)
Not relevant
**)
In the event of a fault: extended fault code (see section 6.5)
The composition of this fault message is described in chapter
6.4 Diagnosis via the field bus" and in the system manual for
the SPC200.