beautypg.com

Festo Кабели и принадлежности User Manual

Page 109

background image

A. Technical appendix

A−21

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Read fault message

Command Message, WRC = 25

d

Byte

Function

Contents

Byte 0

Control byte

LOAD = 1 (see section 5.2.3)

Byte 1

Subindex

1:

Current fault message

2...16: Diagnostic memory

Byte 2

Command Message type

CMT = 25

d

Byte 3

Response Message type

0 (no update permitted)

Byte 4...8

Cmd. Data

Not relevant

Response Message

Byte

Function

Contents

Byte 0

Status byte

LOAD COMPLETED = 1 (see section 5.2.3)

Byte 1

*)

Byte 2

Fault code

See fault treatment in section 6.5

Byte 3

RMT

Copy from byte 2 of the Command Message

Byte 4

Resp. Data 1

**)

Diagnostic word 1 (LB)

**)

Byte 5

Resp. Data 2

Diagnostic word 1 (HB)

Byte 6

Resp. Data 3

Diagnostic word 2 (LB)

Byte 7

Resp. Data 4

Diagnostic word 2 (HB)

*)

Not relevant

**)

In the event of a fault: extended fault code (see section 6.5)

The composition of this fault message is described in chapter
6.4 Diagnosis via the field bus" and in the system manual for
the SPC200.