5. Data structure
5−15
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Composition of the Command Message
Byte
0
1
2
3
4
5
6
7
Command
Message
Control
byte
Subindex
CMT
RMT = 0
Command Data
Byte 0: Control byte
The control signals are explained in chapter 5 of the system
manual for the SPC200. With the parameter commands,
bit 7
(= LOAD) is also used for the LOAD DATA handshake.
Byte 1: Subindex
Depending on the CMT, the subindex contains the number of
the addressed flag group or the number of another target
address in the SPC200.
Byte 2: CMT
The Command Message type is composed as follows:
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
CMT
Command Axis
Number C−AN
Write/Read Command WRC
The following applies for the
axis numbers (C−AN):
Axis numbers
Bit 7
Bit 6
Bit 5
C−AN
X−axis
0
0
0
0 (=> 0h)
Y−axis
0
0
1
1 (=> 20h)
Z−axis
0
1
0
2 (=> 40h)
U−axis
0
1
1
3 (=> 60h)
The
WRC defines the command in question, e.g. WRC = 17
h
would be the command Read the selected record number"
(see overview of commands at the end of this chapter and in
the appendix).
Byte 3
Must be 0 with parameter commands (no update).
Bytes 4...7
Contain the data to be written.