A. Technical appendix

A−7

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

A.3

DeviceNet profiles: Parameter commands

Write Position Register

Command Message, WRC = 1

d

/ 2

d

Byte

Function

Contents for signed 32 bit Contents for float 32 bit

Byte 0

Control byte

LOAD = 1 (see section 5.2.3)

Byte 1

Subindex

Subindex 1...100

Z Position register 0...99

Byte 2

Command Message type

X=1

d

, Y=33

d

, Z=65

d

, U=97

d

X=2

d

, Y=34

d

, Z=66

d

, U=98

d

Byte 3

Response Message type

0 (no update permitted)

Byte 4

Cmd. Data 1

Position value

9999990

9999990 Ģm

Position value

9999 990

9999 990 mm

Byte 5

Cmd. Data 2

−9999990 ... +9999990 Ģm

−9999.990 ... +9999.990 mm
When written the values are

d d

fi

f

Byte 6

Cmd. Data 3

rounded to two figures after
the decimal point.

Byte 7

Cmd. Data 4

the decimal point.

Response Message

Byte

Function

Contents

Byte 0

Status byte

LOAD COMPLETED = 1 (see section 5.2.3)

Byte 1

*)

Byte 2

Fault code

See fault treatment in section 6.5

Byte 3

RMT

Copy from byte 2 of the Command Message

Byte 4

Resp. Data 1

*)

or extended fault code (see section 6.5)

Byte 5

Resp. Data 2

*)

Byte 6

Resp. Data 3

*)

Byte 7

Resp. Data 4

*)

*)

Not relevant