A. Technical appendix

A−13

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Read Position Register

Command Message, WRC = 16

d

/ 17

d

Byte

Function

Contents for signed 32 bit

Contents for float 32 bit

Byte 0

Control byte

LOAD = 1 (see section 5.2.3)

Byte 1

Subindex

Subindex 1...100

Z Position register 0...99

Byte 2

Command Message
type

X=16

d

, Y=48

d

, Z=80

d

, U=112

d

X=17

d

, Y=49

d

, Z=81

d

, U=113

d

Byte 3

Response Message
type

0 (no update permitted)

Byte 4

Cmd. Data 1

Not relevant

Byte 5

Cmd. Data 2

Byte 6

Cmd. Data 3

Byte 7

Cmd. Data 4

Response Message

Byte

Function

Contents for signed 32 bit

Contents for float 32 bit

Byte 0

Status byte

LOAD COMPLETED = 1 (see section 5.2.3)

Byte 1

*)

Byte 2

Fault code

See fault treatment in section 6.5

Byte 3

RMT

Copy from byte 2 of the Command Message

Byte 4

Resp. Data 1

Position value

9999990

9999990 Ģm

**)

Position value

9999 990

9999 990 mm

**)

Byte 5

Resp. Data 2

−9999990 ... +9999990 Ģm

**)

−9999.990Ă...Ă+9999.990Ămm

**)

Byte 6

Resp. Data 3

Byte 7

Resp. Data 4

*)

Not relevant

**

) In the event of a fault: extended fault code (see section 6.5)

This manual is related to the following products: