5. Data structure
5−3
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
5.1
DeviceNet IO: I/O assignment and functions
The following tables provide an overview of the I/O assignĆ
ment and functions of the field bus module type
SPC200−COM−DN2 when it is operated in the protocol variant
DeviceNet IO".
Please note
The protocol variant DeviceNet IO is compatible with the
field bus module type SPC200−COM−CAN in version 1.2.
SPC200−COM−CAN
The field bus module with the type designation SPC200−COM−
CAN provides exclusively the functions described in this
section. The functions of the protocol variant DeviceNet
profiles" are not available.
The signals in the first bytes are described in chapter 5 of the
system manual for the SPC200.
Note also the sequence plans in section A.4 of this manual.
Please note
Outputs of the master are mapped on inputs of the field
bus module; outputs of the field bus module are mapped
on inputs of the master.