beautypg.com

3 i/o address ranges of the field bus module, I/o address ranges of the field bus module – Festo Кабели и принадлежности User Manual

Page 51

background image

4. Commissioning

4−13

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

4.1.3

I/O address ranges of the field bus module

Configurable I/O address range

Depending on the protocol variant and the operating mode,
field bus module SPC200−COM−DN2 provides the following
I/O address ranges:

Protocol
variant

Operating
mode

I/O address
range

*)

I/O byte

Functions

DeviceNet IO

Start/Stop

I10.0 ... I10.15

2 bytes

Control signals and freely
programmable inputs

I11.0 ... I13.15

0, 2, 4, 6
bytes

Freely programmable inputs (optional)

Q10.0 ... Q10.15

2 bytes

Control signals and freely
programmable outputs

Q11.0 ... Q13.15

0...6 bytes

Freely programmable outputs (optional)

Record Select

I10.0 ... I10.15

2 bytes

Control signals

I11.0 ... I11.9

2 bytes

Record number

Q10.0 ... Q10.15

2 bytes

Control signals

DeviceNet
profiles

(always)

I10.0 ... I13.15

8 bytes

For exact assignment see section 5.2.

profiles

Q10.0 ... I13.15

8 bytes

*)

I/O address range of the field bus module; address specifications as viewed by the SPC200

Read example: You are using the field bus module in the
protocol variant DeviceNet IO and the SPC200 in Start/Stop
mode. Besides the control signals in I/Q 10 (2 bytes each),
you wish to use a further two bytes of freely programmable
inputs/outputs. You then assign IĂ10.0 ... IĂ11.15 (= 4 bytes)
and QĂ10.0 ... QĂ11.15 (= 4 bytes).

An overview of all address ranges of the SPC200 (IĂ0...13,
QĂ0...13) can be found in section 1.5.

This manual is related to the following products: