Start program or nc record, Start nc program in start/stop mode – Festo Кабели и принадлежности User Manual
Page 115
A. Technical appendix
A−27
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Start program or NC record
Prerequisites
Ĉ The program must already be saved in the program memory
Ĉ The axis, application and system data must be set correctly
Ĉ The operating mode must be set
Ĉ The SPC200 is ready to operate (1−signal at ENABLE and at STOP
input and at READY output)
Start NC program in Start/Stop mode
In the operating mode Start/Stop the sequence is started or
continued with a rising signal edge at the START input. There
must be a 1−signal at the STOP input.
If there is a 0−signal at the STOP input, a Program Reset will
be triggered by a rising edge at the START input.
Set START
Reset START
Wait 10 ms
Start: Process NC program
in Start/Stop mode
Prepare new start
NC program will be started
Debounce time
End
Fig. A/5:
Start NC program in Start/Stop mode