A. Technical appendix
A−16
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
Read flags and axis status flags
Command Message, WRC = 21
d
Byte
Function
Contents
Byte 0
Control byte
LOAD = 1 (see section 5.2.3)
Byte 1
Subindex
1...4 = flags F0...F63
5...8 = axis status flags F64...127
Byte 2
Command Message type
21
d
Byte 3
Response Message type
0 (no update permitted)
Byte 4
Cmd. Data 1
Not relevant
Byte 5
Cmd. Data 2
Byte 6
Cmd. Data 3
Byte 7
Cmd. Data 4
Response Message
Byte
Function
Contents
Byte 0
Status byte
LOAD COMPLETED = 1 (see section 5.2.3)
Byte 1
*)
Byte 2
Fault code
See fault treatment in section 6.5
Byte 3
RMT
Copy from byte 2 of the Command Message
Byte 4
Resp. Data 1
**)
F0...7, F16...23, F32...39, F48...55
F64...71, F80...87, F96...103, F112...119
**)
Byte 5
Resp. Data 2
F8...15, F24...31, F40...47, F56...63
F72...79, F88...95, F104...111, F120...127
Byte 6
Resp. Data 3
*)
Byte 7
Resp. Data 4
*)
Not relevant
**)
In the event of a fault: extended fault code (see section 6.5)