5. Data structure

5−12

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Composition of the Response Message

The SPC200 replies as follows:

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

MC_B

MC_A

SYNC_OB

SYNC_OA

READY

1

2

Fault code (see section 6.5)

3

Response Axis Number R−AN

Response type RT

4

Response Data 1 (or extended fault code, see section 6.5)

5 ... 7

Response Data 2 ... 4

The values in the bytes mean:

Byte

Function

Contents of actual position

Contents of FB output

RT = 1

RT = 2

RT = 3

RT = 4

Byte 0

Status byte

See system manual for the SPC200

Byte 1

(Diverse)

Byte 2

Fault code

If there is no fault = 0.
With fault code > 0: see fault treatment in section 6.5.

Byte 3

RMT

Copy of Command Message byte 3

Byte 4

Response Data 1
(LW, LB)

Actual position
in signed 32"

*)

Actual position
in float 32"

*)

FB output
Q10.0...Q10.7

*)

FB output
Q12.0...Q12.7

*)

Byte 5

Response Data 2
(LW, HB)

Actual position
in signed 32"

Actual position
in float 32"

FB output
Q10.8...Q10.15

FB output
Q12.8...Q12.15

Byte 6

Response Data 3
(LW, LB)

Actual position
in signed 32"

Actual position
in float 32"

FB output
Q11.0...Q11.7

FB output
Q13.0...Q13.7

Byte 7

Response Data 4
(HW, HB)

Actual position
in signed 32"

Actual position
in float 32"

FB output
Q11.8...Q11.15

FB output
Q13.8...Q13.15

*)

Or extended fault code, see section6.5.