6. Diagnostic and error treatment
6−6
Festo P.BE−SPC200−COM−CANDN−EN en 0511a
6.3
Diagnosis with WinPISA
In the menu [Online] you can look at important system data
of the SPC200 with the command [Diagnosis] [Status display].
The register card [Field bus] shows information about the
field bus connection.
Fig. 6/1:
WinPISA status display Field bus"
Status
Description
Field bus type
Protocol of the installed field bus module
Connection
Parametrizing (when starting up)
Online
Running
Idle
Fault: Firmware < 4.9
Fault: HW, CAN
Bus address
Set field bus address
Baud rate
Current transmission rate
I/O configuration
Number of I/O bytes used for communication
1)
Software version
Software version number of the field bus module
1)
The entry 0I/0O byte means that the master has not yet specified an I/O field size.