beautypg.com

Allied Telesis AT-S39 User Manual

Page 54

background image

Section II: Local and Telnet Management

54

Returning the AT-S39 Software to the Factory Default Values

The procedure in this section returns all AT-S39 software parameters to
their default values. This procedure also deletes any VLANs that you
have created on the switch.

Note
The AT-S39 software default values can be found in Appendix A,
AT-S39 Default Settings on page 312.

To return the AT-S39 management software to its default settings,
perform the following procedure:

1. From the Main Menu, type 5 to select System Config Menu.

2. From the System Configuration Menu, type 8 to select Reset to

Factory Defaults.

The following prompt is displayed:

Are you sure you want to reset to Factory Defaults?

[Yes/No] ->

3. Type Y for yes or N for no.

The following prompt is displayed:

Do you want to reset IP, Subnet and Gateway as well?

[Yes/No] ->

4. If you type Y for yes, all switch parameters including the IP address,

subnet mask, and gateway address are changed to their default
values. If you type N for no, all switch parameters excluding the IP
address, subnet mask, and gateway address are changed to their
default values.

The following prompt is displayed:

The Factory Defaults take effect only after the

Switch reboots.

Do you want to Reboot the Switch now? [Yes/No] ->

5. Type Y to reset the switch.

The operating parameters are returned to their default values and
the switch is reset.

Caution

The switch will not forward traffic during the brief period required to
reload its operating software. Some data traffic may be lost.