beautypg.com

Configuring the interval timer – Allied Telesis AT-S39 User Manual

Page 188

background image

Section II: Local and Telnet Management

188

Configuring the Interval Timer

To set the interval timer for the Broadcast Storm Control feature,
perform the following procedure:

1. From the Main Menu, type 5 to select System Config Menu.

2. From the System Configuration Menu, type A to select Advanced

Configuration.

3. From the Advanced Configuration Menu, type 2 to select Broadcast

Timers Setup.

The Broadcast Storm Control menu in Figure 49 is displayed.

Figure 49 Broadcast Storm Control Menu

4. Type 1 or 2 and enter a value when prompted.

The interval timer for 10 Mbps and 100 Mbps ports is in
milliseconds and has a range of 10 to 120 milliseconds. The value
should be entered in increments of 10.

The interval timer for 1000 Mbps ports is in microseconds and has
a range of 100 to 120000 microseconds. The value should be
entered in increments of 100.

A value for an interval timer applies to all ports operating at the
corresponding speed.

Note
The 1000 Mbps speed applies only to GBIC modules in
AT-8024GB switches and expansion modules in an AT-8016F Series,
AT-8012M, and AT-8024M switch.

Allied Telesyn Ethernet Switch AT-8024

Login Privilege: Manager

Broadcast Storm Control

1 - Timer for 10/100 MB ports ..... 10 milli sec
2 - Timer for 1000 MB ports ....... 100 micro sec

S - Save Configuration Changes
R - Return to Previous Menu

Enter your selection?