You log in as a Manager or an Operator by entering the appropriate
password when you start an AT-S39 management session. The default
password for Manager access is “friend”. The default password for
Operator access is “operator”. Logins and passwords are case-sensitive.
To change the Manager or Operator password, perform the following
procedure:
1. From the Main Menu, type 4 to select Administrator Menu.
2. From the Administrator Menu, type 7 to select Set Password. The
Passwords Menu in Figure 7 is displayed.
Figure 7 Passwords Menu
3. Type 1 to change the Manager password or type 2 to change the
Operator password.
4. When prompted, enter the current Manager or Operator password.
5. When prompted, enter the new Manager or Operator password.
6. When prompted, re-enter the new Manager or Operator password.
Note
The password can be from 0 to 20 alphanumeric characters. Logins
and passwords are case-sensitive.
Note
The two passwords should be different. If both passwords are the
same, the management software will always assume that you wish
to log in as Manager.
Allied Telesyn Ethernet Switch AT-8024
Login Privilege: Manager
Passwords Menu
1 - Set Manager Password
2 - Set Operator Password
R - Return to Previous Menu