beautypg.com

Allied Telesis AT-WA7500 User Manual

Page 78

background image

3 - Configuring the Ethernet Network

78

Table 12 Example 1 - Filter Expressions

You must enter a filter expression for each Value ID in the Filter Values
menu. In this example, only the ExprSeq value and the Value ID value
change.

Parameter

Value

Explanation

ExprSeq

10

The order that you want the expressions executed. You must
have an expression for each Value ID that is listed in the Filter
Values menu.

Offset

0

Since the filter is applied to the destination address, which is
the first value in the frame, the offset is 0.

Mask

ff ff ff ff ff ff

Compares the entire 6-byte destination address for an exact
match.

Op

EQ

Compares the value after the offset and mask are applied to
the value of the Value ID from the Filter Values menu to see if
they are equal. (If the value at the offset equals the specified
value on the Filter Values menu, the frame is multicast.)

Value ID

1

This filter expression applies to value ID 1 from the Filter Values
menu.

Action

Pass

If this filter expression is true, continue to the next expression.