9.6.10 Thermal Camera Menu
01. Control: Sets the type of control on the thermal
camera.
• Internal: The camera configuration is
managed by the pan & tilt.
• External: The camera configuration is
managed through the RS485-3 serial line
(only for models with double camera)
02. Configuration: To set one of the preset
configurations of the thermal camera.
• Standard: Sets the standard configuration of
the thermal camera.
• High Gain: Sets the configuration for a
higher-resolution image.
• Isotherm: Sets the configuration for
highlighting objects within a given
temperature range ("9.6.10.8 Thermal Analysis
Menu (Isotherm)", page 43).
• Custom: Signals that the operator has
manually chosen the configuration of the
thermal camera.
03. Flat Field Correction: Allows access to the Flat
Field correction management submenu.
04. Video Setup: Allows access to the video
configuration management submenu.
05. Gain control: Allows access to the gain control
management submenu.
06. ROI Setup: Allows access to the ROI
management submenu.
07. Thermal Analysis: Allows access to the thermal
analysis management submenu.
08. Status: Allows access to the submenu
containing the technical features of the thermal
camera.
THERMAL CAMERA
------------------------
1>CONTROL : INTERNAL
2 CONFIG. : STANDARD
3 FLAT FIELD CORRECTION>
4 VIDEO SETUP >
5 GAIN CONTROL >
6 ROI SETUP >
7 THERMAL ANALYSIS >
8 STATUS >
Fig. 84
9.6.8 Default menu
01. Delete Setup: Resets all the parameters except
the Presets.
02. Delete Preset: Deletes all previously stored
presets.
DEFAULT
------------------------
1>DELETE SETUP?
2 DELETE PRESET?
Fig. 82
h
The above mentioned operations cause the
loss of all previously stored data (i.g. Preset,
Patrol, Autopan, Home…).
9.6.9 Info Menu
The menu is used to check the configuration of the
device and the installed firmware version.
INFO
------------------------
Address: 1
Protocol: MACRO
RS485-1: 38400 N81 RX
RS485-2: 38400 N81 RIPET
HW: 0a (Apr 14 2009)
FW: 000-0000
Camera : 36x
PC: UC1PSSA000A
SN: 109032220029
Fig. 83