9.6.10 Thermal Camera Menu

01. Control: Sets the type of control on the thermal

camera.
Internal: The camera configuration is

managed by the pan & tilt.

External: The camera configuration is

managed through the RS485-3 serial line
(only for models with double camera)

02. Configuration: To set one of the preset

configurations of the thermal camera.
Standard: Sets the standard configuration of

the thermal camera.

High Gain: Sets the configuration for a

higher-resolution image.

Isotherm: Sets the configuration for

highlighting objects within a given
temperature range ("9.6.10.8 Thermal Analysis
Menu (Isotherm)", page 43
).

Custom: Signals that the operator has

manually chosen the configuration of the
thermal camera.

03. Flat Field Correction: Allows access to the Flat

Field correction management submenu.

04. Video Setup: Allows access to the video

configuration management submenu.

05. Gain control: Allows access to the gain control

management submenu.

06. ROI Setup: Allows access to the ROI

management submenu.

07. Thermal Analysis: Allows access to the thermal

analysis management submenu.

08. Status: Allows access to the submenu

containing the technical features of the thermal
camera.

THERMAL CAMERA

------------------------

1>CONTROL : INTERNAL

2 CONFIG. : STANDARD

3 FLAT FIELD CORRECTION>

4 VIDEO SETUP >

5 GAIN CONTROL >

6 ROI SETUP >

7 THERMAL ANALYSIS >

8 STATUS >

Fig. 84

9.6.8 Default menu

01. Delete Setup: Resets all the parameters except

the Presets.

02. Delete Preset: Deletes all previously stored

presets.

DEFAULT

------------------------

1>DELETE SETUP?

2 DELETE PRESET?

Fig. 82

h

The above mentioned operations cause the
loss of all previously stored data (i.g. Preset,
Patrol, Autopan, Home…).

9.6.9 Info Menu

The menu is used to check the configuration of the
device and the installed firmware version.

INFO

------------------------

Address: 1

Protocol: MACRO

RS485-1: 38400 N81 RX

RS485-2: 38400 N81 RIPET

HW: 0a (Apr 14 2009)

FW: 000-0000

Camera : 36x

PC: UC1PSSA000A

SN: 109032220029

Fig. 83