3 connection of the power supply – Videotec ULISSE COMPACT THERMAL User Manual
Page 16
EN - English - I
nstruc
tions manual
14
h
The power supply cable should also be
covered by the silicone sheath (01) supplied
for this purpose, and fastened with the
corresponding tie (02). Furthermore, all
signal cables must be grouped together by
means of a strap (03).
01
02
03
Fig. 11
h
The building must be equipped with a
20A maximum bipolar protection circuit
(magneto thermal), that must include a
bipolar automatic-type circuit breaker,
which must also envisage earth fault
current protection (magneto-thermal +
differential) with minimum distance of
3mm between contacts.
J2
L
N
a
Earth
Line
Neutral
Fig. 12
7.1.3 Connection of the power supply
The device is available in versions for different power
supply voltages: the value for the particular device is
shown on its identification label.
g
Always make the base connections with the
power supply disconnected and the circuit-
breaker open.
h
When commencing installation make sure
that the specifications for the power supply
for the installation correspond with those
required by the device.
h
Make sure that the power source and
connecting cables are suitable for the
power consumption of the system.
h
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if the cable is
stretched or pulled.
Fig. 10