7.
Test the network connections and latency between the source-to-destination server and the
application-station-to-destination server. The results of a 2-second test initially appear.
8.
To perform additional tests, select a test time in the Test network connections section, and then click
Test
. The following test times are available:
•
2 seconds
•
5 seconds
•
10 seconds
•
30 seconds
•
60 seconds
If you cannot establish the source-to-destination or application-station-to-destination connection, the Next
button is disabled. Ensure that ports 51125 and 51126 are open between source and destination
servers.
If you establish the source-to-destination or application-station-to-destination connection but the network
test reports a transfer speed below 250 kb/s, the Next button is disabled.
If you establish the source-to-destination or application-station-to-destination connection and the network
test reports a transfer speed of at least 250 kb/s, the Next button is enabled.
CAUTION:
If the application-station-to-destination latency is less than 125 milliseconds, continue with
the migration. Latency greater than 125 milliseconds might cause driver injection issues.
9.
Click Next.
128