HP XP P9000 Performance Advisor Software User Manual
Page 395
Table 41 Metrics and descriptions (continued)
Description
Metric
Metric category
The minimum frontend I/Os
rate on this port over an
Minimum Port IO – Frontend
entire collection interval. For
example, if collection
interval is set to five minutes,
the minimum port IO value
is collected and verified
against the previous value
every one minute, and the
lowest port I/O value
collected in the last five
minutes is considered.
The total IO is obtained by
summing up all the IO of all
The total IO of all the LDEVs
created in a specified RAID
Total IO – Frontend
the LDEVS for the given host
group.
group for the given Host
group over the entire data
collection interval.
NOTE:
If the same host
group is exposed to more
than one PORT then the IOs
to hostgroups is seen on all
PORTS where it is exposed.
Calculation of Total IO
depends on the LDEVS and
not on PORTS, while
summing up, the same
hostgroup is exposed to
more than one PORT, we
are considering only once.
The total IO writes is obtained
by summing up IO writes of
The total IO writes of all the
LDEVs created in a specified
Total IO Writes – Frontend
all the LDEVS for the given
host group.
RAID group for the given
Host group over the entire
data collection interval.
The total IO reads is obtained
by summing up IO reads of
The total IO reads of all the
LDEVs created in a specified
Total IO Reads – Frontend
all the LDEVS for the given
host group.
RAID group for the given
Host group over the entire
data collection interval.
The total IO Miss is obtained
by summing up IO miss of all
The total IO miss of all the
LDEVs created in a specified
Total IO Miss – Frontend
the LDEVS for the given host
group.
RAID group for the given
Host group over the entire
data collection interval.
Each RAID group value is the
sum of the LDEVs in the RAID
group.
The sum total of the frontend
I/Os on all the LDEVs
created in a RAID group.
RAID Group Total IO –
Frontend
The sum total of the frontend
random I/Os on all the
RAID Group Total Random
IO – Frontend
LDEVs created in a RAID
group.
The frontend random read
I/Os on all the LDEVs
created in a RAID group.
RAID Group Random Reads
– Frontend
Metrics and descriptions 395