HP 3PAR T-Class Storage Systems User Manual
Page 145
3PAR InForm Management Console 4.1.0 User’s Guide
320-200231 Rev A
145
Part Number
Part number of the SFP.
Serial Number
Serial number of the SFP.
Revision
SFP's revision level.
Max Speed
Maximum speed allowed by the SFP.
Qualified
Displays whether the SFP has been tested and if the SFP
is supported.
TX Disable
Displays whether the transmit laser is disabled.
TX Fault
Displays whether the transmit laser has a problem.
RX Loss
Displays whether the receive end of the SFP is
experiencing a loss of signal from the host or drive cage.
RX Power Low
Displays whether the SFP receive power is low.
DDM Support
Displays whether the SFP is DDM-capable (Digital
Diagnostic Monitoring).
Column Description
DDM
Type
Identifies the monitored parameters (temperature,
voltage, TX bias, TX power, and RX power).
Unit
The unit of measure used for the monitored parameters.
Value
The current measured value.
Low Threshold
Warning
The manufacturer's recommended lower-limit warning
level.
High Threshold
Warning
The manufacturer's recommended upper-limit warning
level.
Low Alarm
Threshold
The manufacturer's recommended lower-limit alarm
level.