beautypg.com

HP 3PAR T-Class Storage Systems User Manual

Page 134

background image

3PAR InForm Management Console 4.1.0 User’s Guide

134

320-200231 Rev A

Port WWN

Port World Wide Name.

Node WWN

Node World Wide Name.

Type

Indicates whether the port is FC, iSCSI, RCIP, or RCFC.

Rate

Rate that data can be transferred over the port (1 Gbps,
2 Gbps or 4 Gbps). When there is no specified value,

no connection exists.

Connected

Device Type

Type of device that the port is connected to. Free, Disk,

Host, or InServ.

Connected
Device

Name of device that the port is connected to, e.g. host1,
cage0.

Mode

Port firmware mode setting. Ports in Initiator mode are
connected to drive cages and ports in Target mode

export to hosts. Suspended mode is for target ports
that have not yet been initialized by the system (rare).

Peer mode is for Ethernet ports.

State

Current state of the port.

Resources

Total Data

Throughput

The throughput in KIB/sec.

Settings

Connection
Mode

The type of port connection.

Connection

Type

Connection type or port connection setting (Loop,
Point, or Loop-point). When the port is set to Loop-

point, both loop and point-to-point connections are
enabled.

Configured
Rate

Data transfer rate setting (for example,

1 Gbps). Auto indicates that the system automatically
selects the rate.

Max Rate

Maximum rate of connection from the port.

Class 2

Indicates whether Fibre Channel service Class 2 is
Disabled, Ack 1 or Ack 0.

VCN

For fabric attached ports, indicates the VLUN change
notification
setting. When set to Enabled, notices are

generated and sent to the fabric controller. When set to
Disabled, no notification is sent.

This manual is related to the following products: