beautypg.com

Test gbic – ADIC SNC 5100 User Manual

Page 70

background image

SNC 5100

62

Fibre Channel MAP

6-00020-02

Step 2.

Press the Enter key on the service terminal.

If the prompt is not displayed, go to “Service Port MAP” on
page 75.

Step 3.

From the service terminal, enter the

showBox

command.

For more information, see the

"showBox"

command on page 170.

Step 4.

Confirm that the Fibre Channel connections are correctly displayed.
If

showBox

displays the Fibre Channel connections correctly, go to

"Examine Cables"

.

Step 5.

If the Fibre Channel connections do not display correctly in the

showBox

display, remove the GBIC and replace it with a

known-good GBIC.

Go to “Removing the GBIC” on page 82.

Proceed through “Replacing the GBIC” on page 82.

Step 6.

Proceed to

"Test GBIC"

.

Test GBIC

Caution

You must stop I/O at the Fibre Channel host.

Step 1.

With a known-good GBIC installed, confirm that the SNC 5100’s
Fibre Channel connections are correctly displayed by issuing the

showBox

command from the service terminal.

For more information, see the

"showBox"

command on page 170.

Step 2.

If the output of the

showBox

command matches the Fibre Channel

configuration, exit this MAP.

If the output of the

showBox

command, still does not match the

Fibre Channel configuration, remove the known-good GBIC and
reinstall the original GBIC.

Go to

"Examine Cables"

.