Step 2.
Press the Enter key on the service terminal.
If the prompt is not displayed, go to “Service Port MAP” on
page 75.
Step 3.
From the service terminal, enter the
showBox
command.
For more information, see the
Step 4.
Confirm that the Fibre Channel connections are correctly displayed.
If
showBox
displays the Fibre Channel connections correctly, go to
Step 5.
If the Fibre Channel connections do not display correctly in the
showBox
display, remove the GBIC and replace it with a
known-good GBIC.
Go to “Removing the GBIC” on page 82.
Proceed through “Replacing the GBIC” on page 82.
Step 6.
Proceed to
.
Test GBIC
Caution
You must stop I/O at the Fibre Channel host.
Step 1.
With a known-good GBIC installed, confirm that the SNC 5100’s
Fibre Channel connections are correctly displayed by issuing the
showBox
command from the service terminal.
For more information, see the
Step 2.
If the output of the
showBox
command matches the Fibre Channel
configuration, exit this MAP.
If the output of the
showBox
command, still does not match the
Fibre Channel configuration, remove the known-good GBIC and
reinstall the original GBIC.