beautypg.com

Scsichanneltest (x,y) – ADIC SNC 5100 User Manual

Page 201

background image

Diagnostic Commands

193

6-00020-02

SNC 5100

The

fcSlotTest

command performs a confidence test on a Fibre Channel

slot. Substitute for

x

the Fibre Channel slot number you want to test. This

command can be used to test the slot or the cable.

The following example code shows the display for a test Fibre Channel slot 1.

diagmode > fcSlotTest 1

FC 1 [##########] Iterations 72 Errors 0 - PASSED

Fibre Channel Port 1 returns PASSED

value = 0 = 0x0

diagmode > fcSlotTest 2

FC 1 [##########] Iterations 72 Errors 0 - PASSED

Fibre Channel Port 2 returns PASSED

value = 0 = 0x0

The following outputs are examples Fibre Channel port tests that were not
successful. If your test was not succesful, return to the MAP that sent you here.

Unsuccessful Fibre Test 1:

diagmode > fcSlotTest 1

FC 1 [##########] Iterations 7799 Errors 7799 - FAILED

Fibre Channel Port 1 returns FAILED

value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7

Note: If the Fibre Channel “link” LED does not come on, the test will not
pass.

Unsuccessful Fibre Test 2 (cable not plugged in):

diagmode > fcSlotTest 1

FC 1 [##########] Iterations 37 Errors 37 - FAILED

Fibre Channel Port 1 returns FAILED

value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7

scsiChannelTest (x,y)

The SNC 5100 must be in diagnostic mode to use this command and a SCSI
cable must be connected between two SCSI channels.

The

scsiChannelTest

command performs a confidence test on a pair of

SCSI channels. Substitute for

x

and

y

the SCSI channel numbers you want to

test. Parentheses are optional. This command can be used to test the SCSI
interface or the SCSI cable.