GBIC. Specifying the port number is optional.

SN600023 > fcGbicShow

---------------------------------------------------------------

Ctlr : Module :

Module

ID : Code :

Information

---------------------------------------------------------------

1 : 4 : Serial Module Definition Protocol

: Connector Type --------------- SC

: Nominal Speed ---------------- 2.5 Gb/sec

: Link length for 9/125 um ----- 0 meters

: Link length for 50/125 um ---- 5500 meters

: Link length for 62.5/125 um -- 2700 meters

: Vendor Name ------------------ FINISAR CORP.

: Vendor OUI ------------------- 009065

: Vendor Part Number ----------- FTR-8519-3-2.5

: Vendor Revision -------------- 1A

: Vendor Serial Number --------- B2557JC

: Vendor Mfg. Date ------------- 10-26-2000

: RX LOS Implemented ----------- Yes

: TX Fault Implemented --------- Yes

: TX Disable Implemented ------- Yes

2 : 4 : Serial Module Definition Protocol

: Connector Type --------------- SC

: Nominal Speed ---------------- 2.5 Gb/sec

: Link length for 9/125 um ----- 0 meters

: Link length for 50/125 um ---- 5500 meters

: Link length for 62.5/125 um -- 2700 meters

: Vendor Name ------------------ FINISAR CORP.

: Vendor OUI ------------------- 009065

: Vendor Part Number ----------- FTR-8519-3-2.5

: Vendor Revision -------------- 1A

: Vendor Serial Number --------- B2557K2

: Vendor Mfg. Date ------------- 10-26-2000

: RX LOS Implemented ----------- Yes

: TX Fault Implemented --------- Yes

: TX Disable Implemented ------- Yes

--------------------------------------------------------------

Parameter

Value

Meaning

Port

1

The SNC 5100 connection labeled FC1

2

The SNC 5100 connection labeled FC2