Envmonrangeshow – ADIC SNC 5100 User Manual
Page 127
Commands
119
6-00020-02
SNC 5100
Air Outlet Temperature
Nominal
51 C
IO Processor Temperature
Warning
31 C
Input Power:
±
5 Volts
Nominal
5.2 V
Input Power:
±
12 Volts
Nominal
12 V
Local Power
±
2.5 Volts
Nominal
3.3 V
Local Power
±
3.3 Volts
Nominal
3.3 V
Local Power
±
3.3 Volts Aux Nominal
3.29 V
All Power
Nominal
All Temp
Nominal
Sample Count
20
value = 1 = 0x1
envMonRangeShow
The
envMonRangeShow
command specifies operational ranges for the SNC
5100's environmental channels. It displays ranges of values associated with the
Nominal, Warning, and Alarm states for voltage, temperature, and fan/blower
operation according to the channels defined in the
envMonShow
command:
SN600012 > envMonRangeShow
Air Inlet Temp (C):
Nominal: 5 to 45
Warning: 4 <= N < 5 or 45 < N <= 50
Alarm:
N < 4 or N > 50
Air Outlet Temp (C):
Nominal: 5 to 50
Warning: 4 <= N < 5 or 50 < N <= 55
Alarm:
N < 4 or N > 55
IO Processor Temp (C):
Nominal: 5 to 80
Warning: 4 <= N < 5 or 80 < N <= 108
Alarm:
N < 4 or N > 108