beautypg.com

Envmonrangeshow – ADIC SNC 5100 User Manual

Page 127

background image

Commands

119

6-00020-02

SNC 5100

Air Outlet Temperature

Nominal

51 C

IO Processor Temperature

Warning

31 C

Input Power:

±

5 Volts

Nominal

5.2 V

Input Power:

±

12 Volts

Nominal

12 V

Local Power

±

2.5 Volts

Nominal

3.3 V

Local Power

±

3.3 Volts

Nominal

3.3 V

Local Power

±

3.3 Volts Aux Nominal

3.29 V

All Power

Nominal

All Temp

Nominal

Sample Count

20

value = 1 = 0x1

envMonRangeShow

The

envMonRangeShow

command specifies operational ranges for the SNC

5100's environmental channels. It displays ranges of values associated with the
Nominal, Warning, and Alarm states for voltage, temperature, and fan/blower
operation according to the channels defined in the

envMonShow

command:

SN600012 > envMonRangeShow

Air Inlet Temp (C):

Nominal: 5 to 45

Warning: 4 <= N < 5 or 45 < N <= 50

Alarm:

N < 4 or N > 50

Air Outlet Temp (C):

Nominal: 5 to 50

Warning: 4 <= N < 5 or 50 < N <= 55

Alarm:

N < 4 or N > 55

IO Processor Temp (C):

Nominal: 5 to 80

Warning: 4 <= N < 5 or 80 < N <= 108

Alarm:

N < 4 or N > 108